Adapter Stops Responding
Most cases recover without unplugging anything. Start at the top of the ladder and go down only when a step does not help. Then check Known Situations: several have a documented cause and a fix in newer firmware.
The Recovery Ladder
Section titled “The Recovery Ladder”| Step | How | What it clears |
|---|---|---|
| 1. Reconnect | Mission Control 3: Disconnect, then Connect. PyCosmicSDK: close the Device and open a new one. | A stuck session in the host software |
| 2. Reset the adapter | PyCosmicSDK: device.reboot(into=ResetTarget.RUNTIME), then open the adapter again. | Interface roles left configured, a stuck SPI bulk transfer, a busy I3C engine |
| 3. Replug USB | Unplug the adapter’s USB cable, wait 5 seconds, plug it back in. | An adapter that no longer answers any command, including the reset |
| 4. Power-cycle the target | Set the target voltage to 0 V and back, or switch the target’s own supply off and on. | A target that holds the bus or dropped off it |
import timeimport pycosmicsdkfrom pycosmicsdk import Device, ResetTarget
serial = pycosmicsdk.list_devices()[0].serial_number # pick your adapter
with Device.open(serial=serial) as device: device.reboot(into=ResetTarget.RUNTIME)
# The adapter re-enumerates; wait until it is listed again (under 1 s on the bench).while not any(d.serial_number == serial for d in pycosmicsdk.list_devices()): time.sleep(0.1)
with Device.open(serial=serial) as device: print(device.info.fw_version)What a reset keeps and what it does not:
- On firmware 4.6.x and earlier, the multifunction rail can come back at about 3.3 V. The I3C rail switches off, because I3C voltage is never saved.
- Every interface must be initialized again.
- A reset cannot help an adapter that has stopped decoding commands: the reset command never arrives. Replug USB.
Replug, do not just reset, when:
- Every command times out, or PyCosmicSDK raises
AdapterNotAnsweringErroragain on a new handle. - A program crashed, or was killed, in the middle of a transfer.
- The adapter is listed but no program can open it.
Known Situations
Section titled “Known Situations”| Symptom | Firmware | Cause | Fix |
|---|---|---|---|
After an HDR-DDR read, the next I3C command times out and every later one answers I3C_ENGINE_BUSY | 4.6.0 (about 90 % of DDR read cycles); 4.5.1 (about 2 in 300) | The controller answered before the HDR exit pattern finished | Reset the adapter. Fixed in 4.6.1. |
| I3C stops working a few transfers after a very large transfer, with no error on the large one | All | An I3C frame holds at most 32,767 bytes, including the register address. A 32,768-byte frame reports success, drops its last byte and leaves the controller busy. | Reset the adapter and initialize I3C again. Keep frames at 32,767 bytes or less; PyCosmicSDK refuses larger ones. |
| An I3C target disappears after a legacy I2C transfer to its dynamic address | 4.5.1 and earlier | The target read the legacy header as an I3C read of itself | Power-cycle the target (I3C voltage to 0 V and back). 4.6.0 and later refuse that transfer with INVALID_PARAMETER. |
I2C_TARGET_INIT times out after a session that used bulk transfers; the adapter otherwise looks healthy | 4.6.1 and earlier | Bulk staging memory not released | Reset the adapter before starting I2C target mode. Fixed in 4.6.2 (upcoming). |
| After an SPI timeout, every SPI transfer comes back one byte late, with success | 4.6.1 and earlier | The timeout path did not re-initialize the SPI block | Reset the adapter. Fixed in 4.6.2 (upcoming). |
A flash status (WIP) poll over SPI never ends | All | The SPI read clock is above what the wiring supports, so reads come back shifted by one bit | Lower the SPI clock for reads, and bound the poll. Supernova on jumper wires: 20 MHz read clean, 30 MHz shifted. |
| An I2C bus stays stuck (SDA or SCL held low) and the adapter resets itself about 8 s later | 4.6.1 and earlier | The adapter keeps waiting for the stuck bus to free up, until its watchdog restarts it | Open the adapter again after it re-enumerates. If a target holds SDA low, power-cycle it. Fixed in 4.6.2 (upcoming): the transfer ends with a timeout, and a failed scan clears the bus with up to 9 SCL pulses. |
| I2C set above 3 MHz (for example 3.4 MHz) or below 11 Hz reports success, then the bus runs at about 11 Hz or the adapter re-enumerates | 4.6.1 and earlier | The frequency is out of range but accepted. On 4.5.0 and earlier the adapter could re-enumerate; on 4.6.0–4.6.1 the bus runs at about 11 Hz. | Open the adapter again if needed and initialize I2C between 11 Hz and 3 MHz. Fixed in 4.6.2 (upcoming): the request returns INVALID_PARAMETER. |
| I2C commands go unanswered after an arbitration-lost error, then the adapter resets | 4.5.0 | The controller was not re-initialized after the error | Fixed in 4.5.1. |
To check the firmware version and update it, see Updating Firmware.
Collect Information for Support
Section titled “Collect Information for Support”Send these to [email protected]:
-
Adapter, serial number and firmware version:
python -c "import pycosmicsdk; print([(d.model.name, d.serial_number, d.hw_version, d.fw_version) for d in pycosmicsdk.list_devices()])"On Linux, an empty serial number means the udev rule is missing. See Solving USB Connection Issues on Linux.
-
Host: operating system and version, and whether the adapter is on a hub.
-
Software and version: Mission Control 3 (desktop or mc3.binho.io) or PyCosmicSDK (
python -c "import pycosmicsdk; print(pycosmicsdk.__version__)"). -
Actions taken: the last commands before it stopped, the wiring and the target voltage. In Mission Control 3, export the Transaction Log from the tool.
-
What recovered it: reconnect, reset, replug, or none.
-
On Linux: the kernel log from the moment it stopped:
sudo dmesg | tail -n 50.